Metal Fire-Rated Door for Australia
The Metal Fire-Rated Door is configured here for Australia. The figures below are the published catalogue specification of the series; the market section covers what projects in Australia add to it. Send the opening schedule and the glazing you want, and the quotation comes back with the dimensional pack.

Metal Fire-Rated Door · Australia
Metal Fire-Rated Door
The metal line pairs a steel leaf and panic bar with knock-down or welded frames, marked at 20, 45, 60 and 90 minutes. The complete configuration, glass options and finish list are on the door series page.
- Door type
- Metal fire exit door with panic bar · steel frame with a wooden leaf
- Fire rating
- 20 / 45 / 60 / 90 min, catalogue test labels
- Leaf
- Steel leaf, powder-coat finish quoted to order
- Frame
- Knock-down frame · welded frame, per catalogue drawings
- Frame sections
- Standard knock-down · knock-down drywall · face welded · full-profile welded
- Face properties
- Fire resistant · impact resistant · erosion resistant
- Ironmongery
- Panic bar · hinge · closer · lockset · kick plate · latch · door bottom · fireproof strip
- Certification
- AS 1905.1:2015 · AS 1530.4:2014 · EN 1634-1:2014+A1:2018 · CAN/ULCS104 · UL Listed
- Application
- Plant rooms · stairwells · service cores · education · hospital
Engineering
Metal leaf with a panic barThe metal leaf is a steel panel finished by powder coat, hung with a full-width panic bar so a crowd can clear the opening on the way out.
Steel frame with a wooden leafOne build keeps the steel frame and takes a wooden leaf, in the same laminate, HPL and veneer faces as the timber range.
Knock-down or welded frameFrames ship either flat for site assembly or welded as one piece, in the sections the catalogue draws.
Accredited fire certificationThe catalogue lists AS 1905.1:2015, AS 1530.4:2014, EN 1634-1:2014+A1:2018 and CAN/ULCS104, with UL listing and the Intertek, CE, BS, IAS, FSC and HKAS marks.
What Australian spec writers check
The Australian regime is built on testing, not on brand claims. AS/NZS 1170.2 sets the regional wind-load classification, AS 2047 defines how window and door assemblies are tested against wind load, and AS 1288 classifies the glazing itself. A cyclone-rated specification must therefore state the zone class, the tested configuration and the glazing classification for the exact module size.
Adam Alux does not hold AS 2047 test certificates. Engineering against your zone and module schedule is confirmed at quotation, and a finished test window or door can be produced before the production run.
Shipping to Australia
Modules travel to the major Australian ports in export-standard containers, packed upright with edge protection. The container count for your schedule depends on frame depth and glass build-up, so the loading plan comes with the quotation.
Transit and port handling are confirmed per shipment. For coastal projects, the fluorocarbon and anodised finish lines are the standard shortlist against salt-air exposure.
Projects in Australia

villa · day scene
Terrace house, glass rear extension
The original brick frontage stays intact, with a slim-profile aluminium and glass extension reading as a separate volume.

villa · day scene
Dark-clad villa, timber slat screens
Dark-clad street villa with timber slat screens and a corner sauna pavilion.

commercial · day scene
Commercial hall, dark timber
Commercial hall frontage in dark timber with a deep cantilevered canopy.
FAQ
Frequently asked
Do your aluminium windows and doors ship to Australia?
Yes. Modules ship to the major Australian ports in export-standard containers, with the loading plan for your schedule included in the quotation.
How do you handle cyclone zone specifications?
The zone class and the module schedule drive the specification. Engineering and glazing classification are confirmed at quotation against the AS 2047 and AS 1288 requirements, with a test unit available before production.
What is the metal fire-rated door?
It is a steel fire door for industrial and public openings, built either as a metal leaf with a panic bar or as a steel frame with a wooden leaf, marked at 20, 45, 60 and 90 minutes.
Which fire ratings are available?
The catalogue marks the line at 20, 45, 60 and 90 minutes. Values are catalogue fire ratings, quoted against the opening and the wall type.
Keep going
Series, market and range
Send your opening schedule
Series, glazing and finish come back as one quotation for Australia, with the full dimensional pack on PDF and CAD on request.