Hotel Fire-Rated Door for Australia
The Hotel Fire-Rated Door is configured here for Australia. The figures below are the published catalogue specification of the series; the market section covers what projects in Australia add to it. Send the opening schedule and the glazing you want, and the quotation comes back with the dimensional pack.

Hotel Fire-Rated Door · Australia
Hotel Fire-Rated Door
The hotel series is a single-leaf fire door built for guest floors, tested and marked at 20, 45, 60 and 90 minutes. The complete configuration, glass options and finish list are on the door series page.
- Door type
- Single-leaf fire door, per catalogue section drawings
- Fire rating
- 20 / 45 / 60 / 90 min, catalogue test labels
- Leaf
- Wooden leaf · laminate / HPL / wooden veneer
- Frame
- Timber frame standard · steel frame with wooden leaf on one model
- Core
- B1 flame-retardant board with a honeycomb core
- Certification
- AS 1905.1:2015 · AS 1530.4:2014 · EN 1634-1:2014+A1:2018 · CAN/ULCS104 · UL Listed
- Ironmongery
- Concealed closer · fire-certified viewer · fire-certified electronic lock · hinge · latch · lever
- Sealing
- Intumescent fireproof strip with an automatic door bottom
- Application
- Hotel guest rooms · apartment entries
Engineering
Single-leaf fire doorThe series is drawn as a single-leaf fire door for hotel and apartment openings, with the leaf, frame and ironmongery specified as one set.
B1 flame-retardant leaf with a honeycomb coreBehind the face the catalogue describes a B1 flame-retardant board over a honeycomb core, a light sandwich that keeps a wide leaf straight.
Fire-certified hardwareA concealed closer, a fire-certified viewer and a fire-certified electronic lock sit on the standard schedule with heavy-duty hinges and a latch.
Accredited fire certificationCompliance is listed to AS 1905.1:2015, AS 1530.4:2014, EN 1634-1:2014+A1:2018 and CAN/ULCS104 with UL listing and the Intertek, CE, BS, IAS, FSC and HKAS marks.
What Australian spec writers check
The Australian regime is built on testing, not on brand claims. AS/NZS 1170.2 sets the regional wind-load classification, AS 2047 defines how window and door assemblies are tested against wind load, and AS 1288 classifies the glazing itself. A cyclone-rated specification must therefore state the zone class, the tested configuration and the glazing classification for the exact module size.
Adam Alux does not hold AS 2047 test certificates. Engineering against your zone and module schedule is confirmed at quotation, and a finished test window or door can be produced before the production run.
Shipping to Australia
Modules travel to the major Australian ports in export-standard containers, packed upright with edge protection. The container count for your schedule depends on frame depth and glass build-up, so the loading plan comes with the quotation.
Transit and port handling are confirmed per shipment. For coastal projects, the fluorocarbon and anodised finish lines are the standard shortlist against salt-air exposure.
Projects in Australia

villa · day scene
Two-storey villa, two-tone cladding
Wide two-storey villa in white and graphite with a full glass frontage.

villa · day scene
House with deep eave, timber screens
A wide overhanging roof shades sliding doors that open the living area onto a timber deck.

villa · day scene
Coastal house, full-height glazing
A raised concrete deck and full-height glazing turn the elevation toward the water, under a deep shaded veranda.
FAQ
Frequently asked
Do your aluminium windows and doors ship to Australia?
Yes. Modules ship to the major Australian ports in export-standard containers, with the loading plan for your schedule included in the quotation.
How do you handle cyclone zone specifications?
The zone class and the module schedule drive the specification. Engineering and glazing classification are confirmed at quotation against the AS 2047 and AS 1288 requirements, with a test unit available before production.
What is the hotel fire-rated door series?
It is a single-leaf wooden fire door for hotel and apartment openings, marked at 20, 45, 60 and 90 minutes and supplied as a leaf, frame and hardware set.
Which fire ratings are available?
The catalogue marks the series at 20, 45, 60 and 90 minutes across the frame and the leaf. Values are catalogue fire ratings, quoted against the opening.