Apartment Fire-Rated Door for Australia
The Apartment Fire-Rated Door is configured here for Australia. The figures below are the published catalogue specification of the series; the market section covers what projects in Australia add to it. Send the opening schedule and the glazing you want, and the quotation comes back with the dimensional pack.

Apartment Fire-Rated Door · Australia
Apartment Fire-Rated Door
The apartment line is the flat entry door: a single wooden leaf, closed rather than glazed, marked at 20, 45, 60 and 90 minutes. The complete configuration, glass options and finish list are on the door series page.
- Door type
- Single-leaf fire door, per catalogue drawings
- Fire rating
- 20 / 45 / 60 / 90 min, catalogue test labels
- Leaf
- Wooden leaf · laminate / HPL / wooden veneer
- Core
- B1 flame-retardant board with a honeycomb core
- Frame
- Timber frame, per catalogue section drawings
- Certification
- AS 1905.1:2015 · AS 1530.4:2014 · EN 1634-1:2014+A1:2018 · CAN/ULCS104 · UL Listed
- Ironmongery
- Concealed closer · fire-certified viewer · fire-certified electronic lock · latch · lever
- Sealing
- Intumescent fireproof strip with an automatic door bottom
- Application
- Apartment entries · hotel guest rooms
Engineering
Flat entry leafThe series is drawn as a single-leaf fire door for the flat entry, with the leaf, frame and ironmongery matched to one tested build.
B1 flame-retardant leaf with a honeycomb coreA B1 flame-retardant board sits over a honeycomb core, a build that stays flat on a wide leaf and keeps the swing light for a concealed closer.
Closed face for privacyThe entry leaf is solid rather than glazed, with a fire-certified viewer and a fire-certified electronic lock on the standard schedule.
Accredited fire certificationCompliance is listed to AS 1905.1:2015, AS 1530.4:2014, EN 1634-1:2014+A1:2018 and CAN/ULCS104 with UL listing and the Intertek, CE, BS, IAS, FSC and HKAS marks.
What Australian spec writers check
The Australian regime is built on testing, not on brand claims. AS/NZS 1170.2 sets the regional wind-load classification, AS 2047 defines how window and door assemblies are tested against wind load, and AS 1288 classifies the glazing itself. A cyclone-rated specification must therefore state the zone class, the tested configuration and the glazing classification for the exact module size.
Adam Alux does not hold AS 2047 test certificates. Engineering against your zone and module schedule is confirmed at quotation, and a finished test window or door can be produced before the production run.
Shipping to Australia
Modules travel to the major Australian ports in export-standard containers, packed upright with edge protection. The container count for your schedule depends on frame depth and glass build-up, so the loading plan comes with the quotation.
Transit and port handling are confirmed per shipment. For coastal projects, the fluorocarbon and anodised finish lines are the standard shortlist against salt-air exposure.
Projects in Australia

villa · day scene
House with deep eave, timber screens
A wide overhanging roof shades sliding doors that open the living area onto a timber deck.

villa · day scene
Coastal house, full-height glazing
A raised concrete deck and full-height glazing turn the elevation toward the water, under a deep shaded veranda.

apartment · day scene
Apartments, angled sunshades
Pale render with dark metal balcony bands and angled sunshades over floor-to-ceiling framed windows.
FAQ
Frequently asked
Do your aluminium windows and doors ship to Australia?
Yes. Modules ship to the major Australian ports in export-standard containers, with the loading plan for your schedule included in the quotation.
How do you handle cyclone zone specifications?
The zone class and the module schedule drive the specification. Engineering and glazing classification are confirmed at quotation against the AS 2047 and AS 1288 requirements, with a test unit available before production.
What is the apartment fire-rated door?
It is a single-leaf wooden fire door for flat entries and hotel rooms, marked at 20, 45, 60 and 90 minutes and supplied as a leaf, frame and hardware set.
Which fire ratings are available?
The catalogue marks the series at 20, 45, 60 and 90 minutes across the frame and the leaf. Values are catalogue fire ratings, quoted against the opening.