Market · the United States
Institutional Fire-Rated Door for the United States
The Institutional Fire-Rated Door is configured here for the United States. The figures below are the published catalogue specification of the series; the market section covers what projects in the United States add to it. Send the opening schedule and the glazing you want, and the quotation comes back with the dimensional pack.

Institutional Fire-Rated Door · the USA
Institutional Fire-Rated Door
One range for school and hospital openings: a single leaf and an unequal double leaf, marked at 20, 45, 60 and 90 minutes. The complete configuration, glass options and finish list are on the door series page.
- Door type
- Single-leaf · unequal double leaf fire door, per catalogue drawings
- Fire rating
- 20 / 45 / 60 / 90 min, catalogue test labels
- Leaf
- Wooden leaf · laminate / HPL / wooden veneer / solid-colour laminate
- Core
- B1 flame-retardant board with a honeycomb core
- Frame
- Timber frame, colour quoted to order
- Vision panel
- Drawn on part of the range for classroom and ward sightlines
- Certification
- AS 1905.1:2015 · AS 1530.4:2014 · EN 1634-1:2014+A1:2018 · CAN/ULCS104 · UL Listed
- Sealing
- Intumescent fireproof strip with an automatic door bottom
- Application
- Classrooms · wards · treatment rooms · escape corridors
Engineering
Single leaf and unequal double leafThe range draws a single-leaf fire door for classrooms and wards, and an unequal double leaf where a wider opening has to keep a narrow active leaf.
B1 flame-retardant leaf with a honeycomb coreA B1 flame-retardant board over a honeycomb core keeps the leaf flat across a school door and light enough for a self-closer.
Vision panels where they helpPart of the range is drawn with a vision panel, so staff can see into a classroom or a patient room before they open the door.
Accredited fire certificationCompliance is listed to AS 1905.1:2015, AS 1530.4:2014, EN 1634-1:2014+A1:2018 and CAN/ULCS104 with UL listing and the Intertek, CE, BS, IAS, FSC and HKAS marks.
What US projects require
Glazing rules tighten in the high-velocity hurricane zones: the code requires impact-rated glazing and defined structural performance on the exterior envelope, and most spec writers work from the ASTM and Florida building code framework as the reference point. In practice the glazing build-up, the frame section and the hardware have to be stated on the quotation, line by line, against your zone and wind-borne debris category.
Adam Alux does not hold US test certifications. The bridge is the specification process: send the zone, the debris category and the opening schedule, and the glazing build-up, frame section and hardware layout come back confirmed against that project at quotation, with a finished test unit available before production.
Shipping to US ports
Modules ship in export-standard containers sized around the opening: glazed units travel upright with corner and edge protection for the trans-Pacific line. The loading plan, including modules per container for your mix, comes with the quotation, because it depends on frame depth and glass build-up rather than a fixed table.
Freight and port handling are confirmed per shipment, and transit time is quoted at order. Packing list and conformity documentation travel with the container.
Projects in the United States

villa · day scene
Single-storey villa, pool terrace
A flat concrete roof with a deep overhang shades full-height sliding doors that open the living space onto a pool terrace.

villa · day scene
Two-storey house, charcoal and timber
A charcoal clad upper volume sits over a timber lower floor, with slim black frames and a cantilevered balcony.

villa · day scene
Suburban house, brick and pivot door
White brick and timber under a low-pitched roof, with black casement windows and a pivot entrance leaf.
FAQ
Frequently asked
Do your aluminium windows and doors ship to the USA?
Yes. The range ships to US ports in export-standard containers, and the loading plan for your opening mix is included with the quotation.
How is hurricane-zone glazing handled on a quotation?
The glazing build-up for a designated zone is confirmed line by line against your debris category at quotation. A finished test unit is available before production.
What is the institutional fire-rated door?
It is a range of single-leaf and unequal double-leaf fire doors for schools and hospitals, marked at 20, 45, 60 and 90 minutes and certified as one assembly.
Which fire ratings are available?
The catalogue marks the range at 20, 45, 60 and 90 minutes. Values are catalogue fire ratings, quoted against the opening and the wall type.
Keep going
Series, market and range
Send your opening schedule
Series, glazing and finish come back as one quotation for the United States, with the full dimensional pack on PDF and CAD on request.