Market · the United States
Hotel Fire-Rated Door for the United States
The Hotel Fire-Rated Door is configured here for the United States. The figures below are the published catalogue specification of the series; the market section covers what projects in the United States add to it. Send the opening schedule and the glazing you want, and the quotation comes back with the dimensional pack.

Hotel Fire-Rated Door · the USA
Hotel Fire-Rated Door
The hotel series is a single-leaf fire door built for guest floors, tested and marked at 20, 45, 60 and 90 minutes. The complete configuration, glass options and finish list are on the door series page.
- Door type
- Single-leaf fire door, per catalogue section drawings
- Fire rating
- 20 / 45 / 60 / 90 min, catalogue test labels
- Leaf
- Wooden leaf · laminate / HPL / wooden veneer
- Frame
- Timber frame standard · steel frame with wooden leaf on one model
- Core
- B1 flame-retardant board with a honeycomb core
- Certification
- AS 1905.1:2015 · AS 1530.4:2014 · EN 1634-1:2014+A1:2018 · CAN/ULCS104 · UL Listed
- Ironmongery
- Concealed closer · fire-certified viewer · fire-certified electronic lock · hinge · latch · lever
- Sealing
- Intumescent fireproof strip with an automatic door bottom
- Application
- Hotel guest rooms · apartment entries
Engineering
Single-leaf fire doorThe series is drawn as a single-leaf fire door for hotel and apartment openings, with the leaf, frame and ironmongery specified as one set.
B1 flame-retardant leaf with a honeycomb coreBehind the face the catalogue describes a B1 flame-retardant board over a honeycomb core, a light sandwich that keeps a wide leaf straight.
Fire-certified hardwareA concealed closer, a fire-certified viewer and a fire-certified electronic lock sit on the standard schedule with heavy-duty hinges and a latch.
Accredited fire certificationCompliance is listed to AS 1905.1:2015, AS 1530.4:2014, EN 1634-1:2014+A1:2018 and CAN/ULCS104 with UL listing and the Intertek, CE, BS, IAS, FSC and HKAS marks.
What US projects require
Glazing rules tighten in the high-velocity hurricane zones: the code requires impact-rated glazing and defined structural performance on the exterior envelope, and most spec writers work from the ASTM and Florida building code framework as the reference point. In practice the glazing build-up, the frame section and the hardware have to be stated on the quotation, line by line, against your zone and wind-borne debris category.
Adam Alux does not hold US test certifications. The bridge is the specification process: send the zone, the debris category and the opening schedule, and the glazing build-up, frame section and hardware layout come back confirmed against that project at quotation, with a finished test unit available before production.
Shipping to US ports
Modules ship in export-standard containers sized around the opening: glazed units travel upright with corner and edge protection for the trans-Pacific line. The loading plan, including modules per container for your mix, comes with the quotation, because it depends on frame depth and glass build-up rather than a fixed table.
Freight and port handling are confirmed per shipment, and transit time is quoted at order. Packing list and conformity documentation travel with the container.
Projects in the United States

villa · day scene
Gable villa, stone and brick
Gable-roof villa mixing white render, stone and brick around deep window reveals.

villa · day scene
Single-storey villa, pool terrace
A flat concrete roof with a deep overhang shades full-height sliding doors that open the living space onto a pool terrace.

villa · day scene
Two-storey house, charcoal and timber
A charcoal clad upper volume sits over a timber lower floor, with slim black frames and a cantilevered balcony.
FAQ
Frequently asked
Do your aluminium windows and doors ship to the USA?
Yes. The range ships to US ports in export-standard containers, and the loading plan for your opening mix is included with the quotation.
How is hurricane-zone glazing handled on a quotation?
The glazing build-up for a designated zone is confirmed line by line against your debris category at quotation. A finished test unit is available before production.
What is the hotel fire-rated door series?
It is a single-leaf wooden fire door for hotel and apartment openings, marked at 20, 45, 60 and 90 minutes and supplied as a leaf, frame and hardware set.
Which fire ratings are available?
The catalogue marks the series at 20, 45, 60 and 90 minutes across the frame and the leaf. Values are catalogue fire ratings, quoted against the opening.
Keep going
Series, market and range
Send your opening schedule
Series, glazing and finish come back as one quotation for the United States, with the full dimensional pack on PDF and CAD on request.




